1 Replacing Synergy Manager Bracket Replacing Synergy Manager Wall Mounting Corrosion Protective Bracket Instructions This manual describes how to replace a wall mounting corrosion protective bracket of Synergy Manager. Figure 1: Three Phase Inverter with Synergy Technology NOTE The Synergy Manager weighs 18 Kg. SolarEdge recommends two people remove the Synergy Manager from the bracket. Kit…
Backup Interface Installation Checklist 1. Installation and Wiring at the Backup Interface 1.1 Check the torque of all the securing bolts for the mounting bracket and conduit holder. ◻ 1.2 Check the torque of all the electrical connections inside the Backup Interface ◻ 1.3 Take a photograph of the Backup Interface connection area (useful for future debugging, if necessary). ◻ 1.4 If required,…
Communication Board Replacement in Single Phase Inverters with HD-Wave Technology and SetApp Kit Contents Communication board Required Tools 4mm hex key Phillips screwdriver 3mm flat screwdriver Removing the Inverter Cover If the inverter cover is not already removed, use the following procedure for cover removal. To remove the inverter cover 1. Turn the inverter ON/OFF/P switch to OFF. Wait 5…