DC Board Replacement in Three Phase Inverters Kit Contents DC board Required Tools 5mm hex key Phillips screwdriver Torque wrench Removing the Inverter Cover 1. Move the inverter ON/OFF/P switch to OFF. Wait 5 minutes for the capacitors to discharge. 2. Switch off the Safety Switch (if applicable). 3. Disconnect the AC to the inverter by turning OFF the circuit breakers on the distribution…
1 MAN-01-00137-1.9 ZigBee/Wi-Fi Antenna Installation NOTE For maximum range, make sure to position the antenna upright. NOTE This option is only applicable for StorEdge Single Phase Inverters. 1.8” / 45 mm ZigBee/Wi-Fi Antenna Installation Kit Contents Antenna with the attached clip and cable Safety Information Please review the following safety guidelines, and observe them when handling the…