`1 2 B. Install the circuit breaker 3 OFF Main Service Panel 1 5 OFF 2 Main breaker switch applicable for BI-E only OFF 3 17 in*lbs 23 in*lbs 6 A. Power off the system and open the Backup Interface Inverter Circuit Breaker Installation for connecting an additional inverter to the Backup Interface (BI-N and BI-E models) ELECTRICAL SHOCK HAZARD C. Mount the dead front D. Connect an additional…
Revision 1.0, November 2020 1 Application Note–Backup Interface Installation Best Practices Application Note–Backup Interface Installation Best Practices Revision History Revision 1.0 - November 2020 Initial release Introduction SolarEdge’s Backup Interface is designed to create a microgrid during power outages by disconnecting the home from the grid. This application note provides information…
Version 1.5 December 2023 Energy metering for SolarEdge three-phase inverters - Application Note 1 Energy metering for SolarEdge commercial three- phase inverters - Application Note This document describes the connection and configuration for energy meters connected to a SolarEdge device. This specific set-up may also be used for export limitation applications. Revision history Version 1.5,…