`1 2 B. Install the circuit breaker 3 OFF Main Service Panel 1 5 OFF 2 Main breaker switch applicable for BI-E only OFF 3 17 in*lbs 23 in*lbs 6 A. Power off the system and open the Backup Interface Inverter Circuit Breaker Installation for connecting an additional inverter to the Backup Interface (BI-N and BI-E models) ELECTRICAL SHOCK HAZARD C. Mount the dead front D. Connect an additional…
Main Service Panel Backed-up Loads Panel 3 Installation and Operation Guide SolarEdge Home Backup Interface for use with the SolarEdge Home Hub Inverter – Single Phase For Australia 2 1 x 3 2 Connect Backup Interface 1. Turn off connection to grid by switching off the main circuit breaker. 2. Thread the L1, Neutral and Ground wires from the Main Service panel through the supplied ferrite bead.…